Linear analysis of pneumatic dashpot damping
Institution: | Missouri University of Science and Technology |
---|---|
Department: | |
Year: | 1970 |
Record ID: | 1511077 |
Full text PDF: | http://hdl.handle.net/10355/40372 |
"The linear analysis of pneumatic damping with orifice or capillary restrictions and with or without mean flow is presented. Temperature and pressure relationships are derived from energy considerations rather than the usual simplification of an assumed polytropic coefficient. Analytical results are compared with the experimental results and a coefficient of heat transfer, Cₕ, is defined for calculation of the equivalent linear damping factor C[subscript d]" – Abstract, page ii.