AbstractsComputer Science

Analysis and feasibility study of a multiple-pass heat and energy recovery ventilator with integrated economizer for residential use

by Jun Long Zhang




Institution: Ryerson University
Department:
Year: 2014
Keywords: Dwellings  – Ontario  – Energy conservation.; Dwellings  – Energy consumption  – Computer simulation.
Record ID: 2027976
Full text PDF: http://digital.library.ryerson.ca/islandora/object/RULA%3A2536


Abstract

The feasibility of a novel total energy recovery ventilator (HERV) was studied, through the use of an Excel-based screening tool developed for cost analysis, and through TRNSYS simulations for performance analysis. Cost analysis indicated that the HERV almost always outperformed the conventional systems, whereas its attractiveness could be limited by its high capital investment. Simulation results indicated that the counter-flow HERV provided better control of house humidity towards the setpoint, in the meantime, minimized the annual energy use. The performance of heat recovery (HRV) and energy recovery (ERV) ventilators was investigated side-by-side at the Archetype Sustainable Twins-House located in Toronto, Canada. The ERV sensible efficiency ranged from 76.4% to78.5% at an outdoor temperature of -20°C and 5°C respectively, while the HRV efficiency ranged from 91.0% to 95.0% at -16.6°C and 0.7°C respectively. Freezing caused a dramatic drop in the efficiency that was found to be as low as 50%.